發布時間:2022-05-13 16:25:00
來源:浙江科為電氣有限公司
篇一:Q/GDW 357-2009《0.2S級三相智能電能表技術規范》宣貫0911
國家電網公司企業標準
(來自: 小 龍 文檔網:三相智能電能表技術規范)
0.2S級三相智能電能表技術規范
Technical specification for class 0.2S polyphase smart electricity meters
宣貫材料
2009-××-××發布
2009-××-××實施
國家電網公司 發 布
目 次
前 言 ··············································································································································· II 1 適用范圍 ······································································································································· 1 2 規范性引用文件····························································································································· 1 3 術語和定義···································································································································· 1 4 技術要求 ······································································································································· 2 5 試驗項目及要求··························································································································· 11 6 檢驗規則 ····································································································································· 14 7 運行質量管理要求 ······················································································································· 15 附錄A 試驗項目明細表 ·················································································································· 17 附錄B 顯示項目表 ························································································································· 19 編制說明 ·········································································································································· 23
I
Q / GDW 357 — 2009
前 言
在國家電網公司“計量、抄表和收費標準化建設研究”項目成果的基礎上,按照統一堅強智能電網建設的總體要求,結合國內外計量、通信技術現狀以及公司系統生產、經營、管理對電能表的基本要求,國家電網公司組織編制了智能電能表系列標準。本系列標準包括《智能電能表功能規范》、《單相智能電能表型式規范》、《三相智能電能表型式規范》、《0.2S級三相智能電能表技術規范》、《0.5S級三相智能電能表技術規范》、《0.5S級三相費控智能電能表(無線)技術規范》、《1級三相費控智能電能表(無線)技術規范》、《1級三相費控智能電能表(載波)技術規范》、《1級三相費控智能電能表技術規范》、《1級三相智能電能表技術規范》、《單相智能電能表技術規范》、《智能電能表信息交換安全認證技術規范》等12個標準。標準編制參考了有關標準、規程、規范。
本標準以《智能電能表功能規范》、《三相智能電能表型式規范》為基礎,對0.2S級三相智能電能表的技術要求、檢驗規則以及運行質量管理等要求做了進一步的規定。本標準是公司系統0.2S級三相智能電能表招標采購、檢驗驗收及質量監督等工作的技術依據。
本標準由國家電網公司營銷部提出并負責解釋。
本標準由國家電網公司科技部歸口。
本標準起草單位:中國電力科學研究院、河南省電力公司、華北電網有限公司、北京市電力公司、山東電力集團公司、江蘇省電力公司、浙江省電力公司、安徽省電力公司、吉林省電力有限公司、甘肅省電力公司、湖北省電力公司、國網電力科學研究院、國網信息通信有限公司共計13個單位。
本標準主要起草人:宗建華、盧興遠、周宗發、徐英輝、杜新綱、葛得輝、秦楠、許鈞、林繁濤、劉國躍、張勇紅、張洪明、陽龍、王思彤、劉宣
II
0.2S級三相智能電能表技術規范
1 適用范圍
1.1 本標準適用于公司系統0.2S級三相智能電能表(以下簡稱“電能表”)的招標、檢驗、驗收等工作,它包括技術指標、機械性能、適應環境、功能要求、電氣性能、抗干擾及可靠性等方面的技術要求、驗收要求以及運行質量管理等要求。
1.2 凡本標準中未述及,但在有關國家、電力行業或IEC等標準中做了規定的條文,應按相應標準執行。
【條文解釋】略
2 規范性引用文件
下列標準中的條款通過本標準的引用而成為本標準的條款,其最新版本適用于本標準。除本標準中規定的技術參數和要求外,其余均應遵循最新版本的國家標準、電力行業標準。如果制造單位有自已的標準或規范,原則上采用更高要求的標準。
IEC 62053—22 《0.2S和0.5S級靜止式交流有功電度表的特殊要求》
IEC 62053—23 《2和3級靜止式交流無功電度表的特殊要求》
GB/T 17215.323—2008 《交流電測量設備 特殊要求-第23部分靜止式無功電能表(2級和3級)》 GB/T 17215.322—2008 《交流電測量設備 特殊要求-第22部分靜止式有功電能表(0.2S級和0.5S級)》 GB/T 17215.211—2006 《交流電測量設備 通用要求 試驗和試驗條件- 第11部分:測量設備》 GB/T 17215.301—2007 《多功能電能表特殊要求》
GB/T 15284—2002
GB/T 15464—1995
JJG 596—1999
JB/T 6214—1992
DL/T614—2007
DL/T 645—2007
DL/T 566—1995
DL/T 830—2002
Q/GDW 206—2008
Q/GDW 356—2009
Q/GDW 354—2009 《多費率電能表 特殊要求》 《儀器儀表包裝用通用技術條件》 《電子式電能表》 《儀器儀表可靠性驗證試驗及測定試驗(指數分布)導則》 《多功能電能表》 《多功能電能表通信協議》 《電壓失壓計時器技術條件》 《靜止式單相交流有功電能表使用導則》 《電能表抽樣技術規范》 《三相智能電能表型式規范》 《智能電能表功能規范》
【條文解釋】略
3 術語和定義
3.1 智能電能表 smart electricity meter
1
篇二:0.2S級三相智能電能表專用技術規范
0.2S級三相智能電能表
專用技術規范
目 錄
1 標準技術參數表 -------------------------------------------------------------------- 1 2 項目需求部分 ---------------------------------------------------------------------- 3 2.1 貨物需求及供貨范圍一覽表 -------------------------------------------------------- 3 2.2 必備的備品備件、專用工具和儀器儀表需求表 ---------------------------------------- 4 2.3 圖紙資料提交單位 ---------------------------------------------------------------- 4 2.4 工程概況 ------------------------------------------------------------------------ 5 2.5項目單位技術差異表 --------------------------------------------------------------- 5 3 投標人響應部分 -------------------------------------------------------------------- 5 3.1 投標人響應技術參數和性能要求 ---------------------------------------------------- 5 3.2 投標產品的銷售及運行業績 -------------------------------------------------------- 7 3.3 主要元器件 ---------------------------------------------------------------------- 7 3.4 投標人提供電子文件格式 ---------------------------------------------------------- 8 3.5 投標人檢測設備明細 -------------------------------------------------------------- 8 3.6 投標人提供外協件控制文件 -------------------------------------------------------- 8
1 標準技術參數表
投標人應認真逐項填寫技術參數響應表中投標人響應欄,不允許改動招標人要求值(標準參數值)。如有偏差,請填寫技術偏差表。(打“*”的項目為主要技術參數,如不能滿足要求,將被視為實質性不符合招標文件要求)
1
2
2 項目需求部分
2.1 貨物需求及供貨范圍一覽表
表2 貨物需求及供貨范圍一覽表
3
注:本表每包單獨列表,項目單位可根據實際包數增加本表。
投標人僅對其所投包,在上述相應表格中填寫投標人響應一欄。
2.2 必備的備品備件、專用工具和儀器儀表需求表
表 3 必備的備品備件、專用工具和儀器儀表供貨表
注:1.本表每包單獨列表,項目單位可根據實際包數增加本表。
2.項目單位可根據實際需要增加備品及專用工具。
3. 投標人僅對其所投包,在上述相應表格中填寫投標人響應一欄。
2.3 圖紙資料提交單位
表4 賣方提交的圖紙資料及其接收單位 4
篇三:Q/GDW 363-2009《1級三相智能電能表技術規范》宣貫0911
國家電網公司企業標準
1級三相智能電能表技術規范
Technical specification for class 1 polyphase smart electricity meters
宣貫材料
2009-××-××發布
2009-××-××實施
國家電網公司 發 布
目 次
前言 ································································································································································ II 1 適用范圍 ·················································································································································· 1 2 規范性引用文件 ······································································································································· 1 3 術語和定義 ·············································································································································· 1 4 技術要求 ·················································································································································· 2 5 試驗項目及要求 ······································································································································ 11 6 檢驗規則 ·················································································································································15 7 運行質量管理要求 ··································································································································15 附錄A 試驗項目明細表 ····························································································································17 附錄B 顯示項目表 ····································································································································17 編制說明 ·······················································································································································23
I
Q/GDW 363—2009
前 言
在國家電網公司“計量、抄表和收費標準化建設研究”項目成果的基礎上,按照統一堅強智能電網建設的總體要求,結合國內外計量、通信技術現狀以及公司系統生產、經營、管理對電能表的基本要求,國家電網公司組織編制了智能電能表系列標準。本系列標準包括《智能電能表功能規范》、《單相智能電能表型式規范》、《三相智能電能表型式規范》、《0.2S級三相智能電能表技術規范》、《0.5S級三相智能電能表技術規范》、《0.5S級三相費控智能電能表(無線)技術規范》、《1級三相費控智能電能表(無線)技術規范》、《1級三相費控智能電能表(載波)技術規范》、《1級三相費控智能電能表技術規范》、《1級三相智能電能表技術規范》、《單相智能電能表技術規范》、《智能電能表信息交換安全認證技術規范》等12個標準。標準編制參考了有關標準、規程、規范。
本標準以《智能電能表功能規范》、《三相智能電能表型式規范》為基礎,對1級三相智能電能表的技術要求、檢驗規則以及運行質量管理等要求做了進一步的規定。本標準是公司系統1級三相智能電能表招標采購、檢驗驗收及質量監督等工作的技術依據。
本標準由國家電網公司營銷部提出并負責解釋。
本標準由國家電網公司科技部歸口。
本標準起草單位:中國電力科學研究院、河南省電力公司、華北電網有限公司、北京市電力公司、山東電力集團公司、江蘇省電力公司、浙江省電力公司、安徽省電力公司、吉林省電力有限公司、甘肅省電力公司、湖北省電力公司、國網電力科學研究院、國網信息通信有限公司共計13個單位。
本標準主要起草人:宗建華、盧興遠、周宗發、徐英輝、杜新綱、葛得輝、劉忠、許鈞、姜洪浪、劉國躍、張勇紅、張洪明、陽龍、王思彤、劉宣
II
1級三相智能電能表技術規范
1 適用范圍
1.1 本標準適用于公司系統1級三相智能電能表(以下簡稱“電能表”)的招標、檢驗、驗收等工作,它包括技術指標、機械性能、適應環境、功能要求、電氣性能、抗干擾及可靠性等方面的技術要求、檢驗規則以及運行質量管理等要求。
1.2 凡本標準中未述及,但在有關國家、電力行業或IEC等標準中做了規定的條文,應按相應標準執行。
【條文解釋】略
2 規范性引用文件
下列標準中的條款通過本標準的引用而成為本標準的條款,其最新版本適用于本標準。除本標準中規定的技術參數和要求外,其余均應遵循最新版本的國家標準、電力行業標準。如果制造單位有自已的標準或規范,原則上采用更高要求的標準。
IEC 62053-21 《1和2級靜止式交流有功電能表的特殊要求》
IEC 62053-23 《2和3級靜止式交流無功電能表的特殊要求》
GB/T 15284—2002 《多費率電能表 特殊要求》
GB/T 17215.323—2008 《交流電測量設備 特殊要求-第23部分靜止式無功電能表(2級和3級)》 GB/T 17215.321—2008 《交流電測量設備 特殊要求》第21部分靜止式有功電能表(1級和2級) GB/T 17215.211—2006 《交流電測量設備 通用要求 試驗和試驗條件-第11部分:測量設備》 GB/T 17215.301—2007 《多功能電能表特殊要求》
GB/T 15464—1995 《儀器儀表包裝通用技術條件》
JJG 596—1999 《電子式電能表》
JB/T 6214—1992 《儀器儀表可靠性驗證試驗及測定試驗(指數分布)導則》
DL/T614—2007 《多功能電能表》
DL/T 645—2007 《多功能電能表通信協議》
DL/T 566—1995 《電壓失壓計時器技術條件》
DL/T 830—2002 《靜止式單相交流有功電能表使用導則》
Q/GDW 206—2008 《電能表抽樣技術規范》
Q/GDW 356—2009
Q/GDW 354—2009 《三相智能電能表型式規范》 《智能電能表功能規范》
【條文解釋】略
3 術語和定義
3.1 智能電能表 smart electricity meter
由測量單元、數據處理單元、通信單元等組成,具有電能量計量、數據處理、實時監測、自動控制、
發布時間:2022-05-18 15:56:00
RS-485的2線電壓不斷變化的,從而能傳輸數據樓主說的工作電壓是指什么?RS-485通常是有RS-485收發器芯片來進行數據傳輸這些不同的芯片的工作電壓會有差別的但具體到某個芯片來說是固定的如max485采用單一電源+5V工作,額定電流為300μA,采用半雙工通訊方式。它完成將TTL電平轉換為RS-485電平的功能。MAX485芯片的結構和引腳都非常簡單,內部含有一個驅動器和接收器。
發布時間:2022-05-17 17:06:00
浙江科為電氣有限公司是一家集電子式電能表開發、生產、銷售于一體的科技型企業。公司成立至今,以"成為全球電力測量、控制和服務的核心企業,追求員工與公司共同發展"為目標,將"創新、高效、守信、協作"的企業精神作為公司發展的活力之根和動力之源,通過幾年的不斷努力,公司各項主要經濟指標得到持續增長,目前已成為全球知名電能計量產品的專業制造商之一,
發布時間:2022-05-16 15:05:00
智能電子表如何看用電電度?請先了解一下智能電表:我們經常見到的智能電表,有以下兩種1.三相四線有功電能電子表,(及三相四線無功電表)。2.單
發布時間:2022-05-13 16:25:00
三相智能物聯電能表技術規范 1 范圍 規定了三相智能物聯電能表 (以下簡稱 “電能表”)的規格要求,環境條件,模組化、機械及結構、 電源、功能及包裝要求,計量性能、狀態監測、電氣性能、可靠性、擴展模組互換性等方面的技術要求 和試驗方法,規定了電能表的檢驗規則和運行質量管理要求。
發布時間:2022-05-11 16:33:00
智能電能表的一體化結構設計是非常重要的,首先應做功能分區,硬件分功能模塊化設計,內部無軟件焊接,一體化設計理念;其次要進行先進的軟件架構設計,基于實時操作系統搭建統一應用平臺;另外,要保證安全可靠性,基于文件系統與數據備份機制。
發布時間:2022-05-10 16:36:00
家庭用電能表都是單相電能表,單相電表從左到右有四個接線端依次為1、2、3、4。接線方法為:1和3分別接上輸入電能表的火線和零線端,2和4分別接上輸出電能表的火線和零線端,叫做“兩進兩出”的接法,
發布時間:2022-05-09 17:03:00
220V是電能表的額定工作電壓,5(20)A中5A是指該電能表的基本電流,就是檢測該電能表性能時所用的電流大小,20A是該電能表能長期運行且保證計量準確的最大電流,50Hz是電能表的額定工作頻率,3200imp/KWh樓上的說法有誤,轉圈是指機電式電能表,機電表是用r/KWh表示的。3200imp/KWh中imp是脈沖(impluse)的意思,表示此表每消耗1度電,電表脈沖指示燈閃爍3200次
發布時間:2022-05-05 17:13:00
導軌式安裝電能表的接線方式 直接接入:又叫一次接入經互感器接入:又叫二次接入(1)接入中性點絕緣系統的電能計量裝置,應采用三相三線有功、無功電能表。接入非中性點絕緣系統的電能計量裝置,應采用三相四線有功、無功電能表或3只感應式無止逆單相電能表。
18958809618
COPYRIGHT ? 2020 浙江科為電氣有限公司 ALL RIGHTS RESERVED